Nikkiso Metering Pump

Nikkiso Pulseless Pump

High-precision injection pumps adaptable to a wide range of flow rates, pressures and applications.

Nikkiso Pulseless Pump

1. “Unique designed cam and check valves of NIKKISO PULSELESS SERIES can realize almost zero pulsation with high discharge accuracy. Multi-function mixing of two liquids, Feeding high-viscosity liquid , Precision filling, Wide turndown ratio”

2. Advantages of Pulseless Pumps

  1. There is almost zero pulsation, different from conventional triplex pump.
  2. Unique designed check valves achieves discharge accuracy (±0.5%).
  3. Compact. One cylindrical cam drives two plungers.
  4. Top mounted motor achieves small foot design.
  5. High performance model has been newly added.”

3. Press-Capacity Envelope
Packed plunger ···························Discharge press. max. 30.0MPa (4350 PSIG)
Low press. diaphragm type ········Discharge press. max. 1.5MPa (220 PSIG)
High press. diaphragm type ·······Discharge press. max. 17.5MPa (2530 PSIG)

Nikkiso Metering Pump MX Series

MX Series is designed to meet customer’s needs for Compact Design, Environmentally,Safe, Space Saving, and High Metering Performance. Those needs are realized at every level with state-of-art technologies.

Advantages

  1. Compact and Rugged Design
  2. Space Saving
  3. Long Service Life and Low Maintenance
  4. High Accuracy, High Linearity and Wide Control Range
  5. Various types of liquids and
  6. Electrical and Pneumatic Control
  7. Diaphragm condition Monitoring available
  8. Motor can be installed both vertically and horizontally
  9. Steady State Accuracy: within ±0.5%

Metering Pump API 675

1. Important requirements of API675

  • Rated capacity shall be at least 110 percent of the maximum capacity specified —————————————- Yes
  • The steady state flow accuracy shall be within ±1 percent of rated flow over a turndown ratio of at least 10:1 ————- Yes
  • The flow repeatability shall be within ± 3 percent of rated flow over the specified turndown ratio—————- Yes 
  • Deviation from linearity shall not exceed ± 3 percent of rated flow over the specified turndown ratio ————— Yes
  • Minimum differential pressure required to ensure the specified flow accuracy shall be stated by the vendor in the quotation —Yes.

2. Steady State Accuracy
Steady state accuracy is the flow variation expressed as a percentage of mean delivered flow of rated flow under fixed-system conditions. Steady state accuracy applies over the turndown ratio of 10:1.

Chemical Injection Packages

Taking advantage of the performance of our high-precision metering pumps, the units are optimally-designed systems tailored to customers’ needs

Scroll to Top
Open chat
1
Hello
Can we help you?